A spiral duct section is built from one continuous strip wound around the forming head into a helix, with the edge of each wrap locking over the previous wrap to make one continuous seam. How tightly that seam closes, how round the tube stays along its length, and how straight the finished section runs are decided inside the forming head rather than after the cutoff. A feed that wanders, a mould set for the wrong diameter or gauge, or a strip that enters at an angle all show up as an open overlap, an oval tube or a wandering seam on the first finished section. This guide covers how the helical lock forms in the head, what seam and roundness to check on a finished section, and where common forming defects come from. Machine figures come from the verified PD-1600 and PD-2000 specifications; no unlisted diameter, gauge or output figure is claimed.
How the Spiral Lock Seam Forms
The strip enters the forming head from the feed guide and is bent progressively around the mould as the head rotates. One longitudinal edge of the strip is pressed into the locking profile while the adjacent wrap overlaps it, so each revolution locks onto the previous one along a helical line that runs the full length of the tube. The mould defines the finished circle; the forming rolls shape the strip onto that circle and hold the overlap down so the seam does not lift as the tube advances. Because the seam is formed continuously, a condition set in the head carries through every section off the machine, which is why the first tube of a batch carries the whole setup check.
The strip gauge and width set the working range the mould can hold. Lighter strip forms more easily but can buckle if the overlap pressure is uneven; heavier strip needs the forming rolls and lock profile to press firmly enough to seat the hook without crushing the edge. The PD-1600 fixed-mould head works 137 mm strip in 0.4-1.2 mm gauge for 100-1600 mm duct; the PD-2000 heavy-duty mould-type head handles 0.5-1.5 mm strip up to 2000 mm diameter with a flying shear and slitter arrangement.
What to Check on the First Finished Section
After the mould, rolls and feed are set, one tube section runs through forming and cutoff before the batch continues. The check follows the seam and the profile along the whole length rather than judging one end. Each condition on the first section points back to a specific station: feed guide, mould, forming rolls or strip gauge. A defect repeated down the run traces to that station, not to the cutoff that separates the section.
| Check point | What a good section shows | Setup focus | What a defect points to |
|---|---|---|---|
| Seam overlap | Even overlap along the full helix; hook seated flat, no lifted edge | Lock-forming rolls aligned to the strip edge; overlap pressure matched to gauge | Lifted or uneven overlap points to roll profile or pressure; wandering seam to feed guide |
| Round profile | True circle at both ends and along the length; no flat spots | Mould set to the target diameter; strip feeding centered | Oval or flat-sided tube points to mould setting, feed alignment or gauge outside the band |
| Straightness | Section runs straight; seam helix at an even angle, no bow | Forming head centered on the feed line; strip entering square | Bow or drift along the length traces to guide alignment or an off-center coil |
| Seam tightness | Lock holds together; no gap along the overlap, seam not split open | Roll pressure sufficient for active gauge; strip edge clean and square | Soft or open seam points to worn roll profile, light pressure or a damaged strip edge |
| Cut end | Clean square cut; no burr pulling the seam open at the end | Cutoff matched to the section; head feeding steadily | Rough or angled end points to cutoff setup rather than the forming seam |
PD-1600 and PD-2000 Forming Classes Compared
The two Preda tubeformer classes both wind a continuous helical lock, but their mould type, gauge band and diameter range differ, which changes which duct sizes and thicknesses the head can form cleanly. The PD-1600 is the fixed-mould mid-range machine built around a 1200 kg coiler, feeding 137 mm strip at 1-38 m/min, with roller cutoff standard and plasma cutoff optional. The PD-2000 is the heavy-duty mould-type machine for diameters up to 2000 mm in 0.5-1.5 mm strip at 1-30 m/min, paired with a flying shear and slitter and a 15 kW drive. The table lists the verified machine figures; diameter and gauge outside the rated band call for the next machine class rather than a head adjustment.
| Specification | PD-1600 Spiral Tubeformer | PD-2000 Heavy-Duty Tubeformer |
|---|---|---|
| Finished diameter | 100-1600 mm | Up to 2000 mm |
| Material thickness | 0.4-1.2 mm | 0.5-1.5 mm |
| Working speed | 1-38 m/min | 1-30 m/min |
| Feeding strip | 137 mm strip | Slitter / flying shear arrangement |
| Forming structure | Fixed mould / fixed die | Heavy-duty mould type |
| Coiler capacity | 1200 kg coiler | Heavy-duty coil handling |
| Cutoff | Roller cutoff standard; plasma cutoff optional | Flying shear with slitter |
| Installed power | 11 + 1 kW | 15 kW |
| Weight / footprint | 2000 kg; 5500 x 1800 x 1600 mm | Heavy-duty mould-type frame |
| Certification / warranty | CE certified, two-year warranty | CE certified, two-year warranty |
Gauge, Strip Edge and Seam Quality Move Together
The seam closes cleanly only when the strip entering the head matches the mould and roll setup. Heavier gauge presses harder on the lock profile and needs enough roll pressure to seat the hook; light gauge can be crushed or marked if that pressure stays high. The strip edge should be square and free of burr so the overlap meets the previous wrap evenly; a torn or beveled edge forms a weak or open section along that edge. Before a new diameter or gauge is run, the mould and rolls are checked against the active combination, and the first section is inspected rather than assumed from the last batch.
Diameter changeover sets the mould to the target tube size; the strip width and gauge are checked against the diameter band for that mould. Once the head is set, the feed guide keeps the strip entering square so the helix angle stays even along the run. Seam tightness and roundness on the first section confirm whether the mould, rolls and feed are all tracking together; if one end of the tube is round and the other drifts, the feed or guide has shifted during the run rather than the mould being wrong.
Common Seam and Roundness Defects and Their Source
- Open or lifted overlap: lock-forming rolls short on pressure or profile worn; check roll pressure against gauge and inspect the profile on a reference section.
- Tube comes off oval or flat-sided: mould not set to the diameter, strip feeding off-center, or gauge outside the rated band; check mould setting and feed alignment on the first section.
- Seam wanders along the run: feed guide shifted or coil off-center; realign the guide and recenter the coil before continuing.
- Marked or crushed strip along the seam: roll pressure too high for light gauge; reduce pressure to the active thickness.
- Seam gap appears only after cutoff: rough or angled cut pulling the end open; check cutoff setup and feed steadiness rather than the forming lock.
Keep a reference seam and tube sample per diameter
Save one reference section at a recurring diameter and gauge, and note the mould and roll setting used. When a new run comes off oval or open, compare the overlap and roundness against that sample before changing the mould or rolls.
Frequently Asked Questions
What makes a spiral seam stay closed?
The forming rolls wind each wrap over the previous one and seat the overlap at pressure matched to the strip gauge. A clean square strip edge, a mould set to the diameter and steady centered feed keep the lock tight along the whole helix.
Why does a finished tube come off oval?
Ovality usually traces to the mould not matching the target diameter, strip feeding off-center, or a gauge outside the rated band. Check the mould setting and feed guide on the first section before running more tube.
How does gauge affect the seam setup?
Heavier strip needs enough roll pressure to seat the hook; light gauge is easily marked if pressure stays high. The PD-1600 covers 0.4-1.2 mm, the PD-2000 handles 0.5-1.5 mm; outside those bands the next machine class, not an adjustment, is the answer.
What confirms the forming head is set correctly?
A true circle at both ends and along the length, an even seated overlap with no lifted edge, a straight section with an even helix angle, and a clean cut end. Open overlap, ovality or a wandering seam point back to rolls, mould, guide or strip condition.
Preda Care Service Promise
Every Preda Machine ships CE certified with a two-year warranty, backed by 24/7 technical support, free spare parts shipping, remote PLC programming assistance and a global agent network. A support engineer can review your diameters, gauges and strip widths against the PD-1600 or PD-2000 and confirm the mould, roll and feed setup for tight, round spiral sections.